Cooling of Buried Power Cables by Using Metallic Pipes as an Alternative to Polymeric Pipes-Comparison of Results from Experiments and Simulations

T Beck Sletten - 2016 - ntnuopen.ntnu.no
… conducts heat very well compared to plastic pipes made of … heat in the pipe can be calculated
by the following equation [… the heat lines seems to be forced into the air inside the pipe, …

Steady-state thermal analysis of power cable systems in ducts using streamline-upwind/Petrov-Galerkin finite element method

Y Liang - IEEE Transactions on Dielectrics and Electrical …, 2012 - ieeexplore.ieee.org
cables is considerably higher than that of the overhead lines, … -core power cables are placed
in three PVC pipes as shown … -thermal coupling method for calculating the thermal field and …

Simplified model for heat transport for cables in pipes

SM Hellesø, E Eberg - IEEE Transactions on Power Delivery, 2021 - ieeexplore.ieee.org
… of circuits to be laid in the same trench or are installed in ducts for … calculations of such
cables involve analysis of the heat … The broken line is given by eq (9), the dotted-broken line is …

[HTML][HTML] Thermal assessment of power cables and impacts on cable current rating: An overview

D Enescu, P Colella, A Russo - Energies, 2020 - mdpi.com
… concepts of heat transfer for the calculation of cable rating to … at different points of the cable
lines, as well as in the soil and … cables that cross the streets or pass near other pipelines [74]. …

A 3-D nonlinear thermal circuit model of underground MV power cables and their joints

T Bragatto, M Cresta, FM Gatta, A Geri… - Electric Power Systems …, 2019 - Elsevier
pipe or a duct, a thermal resistance between cable and pipe … the formula [29]:(7) R a i r = 1
h A being h the convective heat … simulate the thermal heating of an MV cable line buried into …

Thermal performance optimization of the underground power cable system by using a modified Jaya algorithm

P Ocłoń, P Cisek, M Rerak, D Taler, RV Rao… - … Journal of Thermal …, 2018 - Elsevier
cables application is associated with heat dissipation from … of the cable line by providing
favorable conditions for heat … studied heat losses from an array of pipes or electric cables

Increasing Reliability of XPLE-Insulated Cables: FEA-Based Ampacity Calculation and Online Monitoring of Insulation Degradation

M Doronin, S Dubitsky, G Greshnyakov… - … IEEE Conference of …, 2021 - ieeexplore.ieee.org
… electromagnetic and thermal influence of several cable lines. … cable is laid in a separate
polyethylene pipe, the fourth pipe … time assessment of electrical cables with polymer insulation in …

Numerical and experimental study of the electrofusion welding process of polyethylene pipes

Z Chebbo, M Vincent, A Boujlal… - Polymer Engineering …, 2015 - Wiley Online Library
… using three polymer cable ties (Fig. 3c). Both ends of the … Existing heat transfer equation
was modified to take into account … the thermal contact resistance either between a polymer and …

The thermal behavior of cable backfill materials

JI Adams - IEEE Transactions on power apparatus and systems, 1968 - ieeexplore.ieee.org
cable, centered in the pipe by plastic runners spaced at … Pa calculated from the pipe
temperature and soil ambient at … 120-kV experimental cable line were investigated with conductor …

Thermal instability in buried cable backfills

TL Brandon, JK Mitchell, JT Cameron - Journal of Geotechnical …, 1989 - ascelibrary.org
… The time at which this constructed line intersects the … to the pipe, and they were used to
measure both thermal resistivity and … calculation methods of moisture and heat transfer in cable